{"id":3553,"date":"2023-03-01T16:08:54","date_gmt":"2023-03-01T16:08:54","guid":{"rendered":"https:\/\/csiag.de\/?p=3553"},"modified":"2025-03-04T10:57:02","modified_gmt":"2025-03-04T10:57:02","slug":"radiacao-ionizante","status":"publish","type":"post","link":"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/","title":{"rendered":"Radia\u00e7\u00e3o ionizante"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_84 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/#Einheiten\" >Unidades<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/#Strahlenarten\" >Tipos de radia\u00e7\u00e3o<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/#Radon_%E2%80%93_als_Heilmittel\" >Rad\u00e3o - como rem\u00e9dio<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/#Messgerate\" >Dispositivos de medi\u00e7\u00e3o<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/#Definition_Grenz-_Richt_und_Referenzwert\" >Defini\u00e7\u00e3o de limite, diretriz e valor de refer\u00eancia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/#Interpretation_der_Messwerte\" >Interpreta\u00e7\u00e3o dos valores medidos<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p class=\"wp-block-paragraph\">A radia\u00e7\u00e3o ionizante \u00e9 impercept\u00edvel para os humanos; \u00e9 inodora, ins\u00edpida e invis\u00edvel. Surge da decomposi\u00e7\u00e3o de \u00e1tomos de subst\u00e2ncias radioativas, que ocorrem em toda a natureza.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Einheiten\"><\/span>Unidades<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">No entanto, esta decad\u00eancia at\u00f4mica pode ser medida. <em>Antoine Henri Becquerel<\/em> recebido em 1903, juntamente com <em>Mary<\/em> e <em>Pedro Curie<\/em>, o Pr\u00eamio Nobel pela descoberta da radioatividade. Depois que a taxa de decaimento, ou seja, o n\u00famero de \u00e1tomos deca\u00eddos por segundo, foi inicialmente dada em Curie (Ci), a unidade Bequerel (Bq) tem sido usada desde 1998.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Depois do m\u00e9dico e f\u00edsico sueco <em>Rolf Sievert<\/em>, em 1979, 13 anos ap\u00f3s sua morte, a unidade sievert (Sv) foi institu\u00edda como unidade internacional de dose equivalente. Descreve a exposi\u00e7\u00e3o (dose) a um organismo biol\u00f3gico em joules por quilograma multiplicada por isso <a href=\"https:\/\/de.wikipedia.org\/wiki\/Strahlungswichtungsfaktor\" target=\"_blank\" rel=\"noreferrer noopener\">Fator de pondera\u00e7\u00e3o do feixe<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9 feita uma distin\u00e7\u00e3o entre equival\u00eancia (H), efetiva (D<sub>ef<\/sub>) e a dose do \u00f3rg\u00e3o (H<sub>T<\/sub>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A dose eficaz leva em considera\u00e7\u00e3o as diferentes sensibilidades dos \u00f3rg\u00e3os. O valor limite para pessoas que n\u00e3o est\u00e3o profissionalmente expostas \u00e0 radia\u00e7\u00e3o<sup>(1)<\/sup> \u00e9 de 1 mSv\/a, para aqueles ocupacionalmente expostos \u00e0 radia\u00e7\u00e3o<sup>(2)<\/sup> a 20 mSv\/a.<br>A dose do \u00f3rg\u00e3o descreve a dose absorvida pelo respectivo \u00f3rg\u00e3o, na Alemanha, por exemplo, o cristalino do olho 15 mSv\/a<sup>(1)<\/sup>, ou 20 mSv\/a<sup>(2)<\/sup>, extremidades 50 mSv\/a<sup>(1)<\/sup>, ou 500 mSv\/a<sup>(2)<\/sup> de acordo com <a href=\"https:\/\/www.gesetze-im-internet.de\/strlschv_2018\/StrlSchV.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">StrlSchV \u00a771<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Strahlenarten\"><\/span>Tipos de radia\u00e7\u00e3o<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dependendo do tipo de radia\u00e7\u00e3o a ser medida, diferentes m\u00e9todos e dispositivos de medi\u00e7\u00e3o est\u00e3o dispon\u00edveis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um contador Geiger com o nome <em>Johannes Wilhelm Geiger<\/em>, ou tubo contador Geiger-M\u00fcller, complementado pelo nome de seu aluno de doutorado <em>Walther M\u00fcller<\/em>, conhecido desde 1929, \u00e9 usado para medir o decaimento radioativo da radia\u00e7\u00e3o alfa, beta e gama. O despacho tamb\u00e9m fornece informa\u00e7\u00f5es sobre a crescente capacidade de penetra\u00e7\u00e3o da radia\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Radia\u00e7\u00e3o alfa<\/strong> (\u03b1) \u00e9 encontrado em n\u00facleos pesados, como o ur\u00e2nio-238.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Radia\u00e7\u00e3o beta<\/strong> (\u03b2) \u00e9 formado quando o n\u00facleo de um \u00e1tomo \u00e9 convertido em outro elemento. Uma distin\u00e7\u00e3o \u00e9 feita aqui entre \u03b2<sup>+<\/sup>, o elemento com o pr\u00f3ximo valor mais baixo e \u03b2<sup>-<\/sup>, o elemento do pr\u00f3ximo n\u00famero at\u00f4mico superior. Ambos s\u00e3o radia\u00e7\u00f5es ionizantes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Radia\u00e7\u00e3o gama<\/strong> (\u03b3) \u00e9 uma radia\u00e7\u00e3o eletromagn\u00e9tica com comprimento de onda de apenas 0,005 nm (correspondendo a 59.958.491,6 THz (!)) e \u00e9 criada ap\u00f3s o decaimento \u03b1 ou \u03b2 da energia liberada no processo, tamb\u00e9m conhecida como transi\u00e7\u00e3o \u03b3. Isto n\u00e3o \u00e9 um decaimento porque o n\u00famero de n\u00eautrons e pr\u00f3tons contidos no n\u00facleo permanece inalterado. Ao passar por um corpo (humano, animal, fruta, etc.), os el\u00e9trons liberados e os raios X resultantes quebram as liga\u00e7\u00f5es qu\u00edmicas, causando danos \u00e0s c\u00e9lulas e ao DNA, entre outras coisas.<br>O <em>Fator de pondera\u00e7\u00e3o de radia\u00e7\u00e3o<\/em> \u00e9 1 e serve de refer\u00eancia para outros tipos de radia\u00e7\u00e3o quanto \u00e0 sua nocividade ao organismo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>rad\u00f4nio<\/strong> (Rn) \u00e9 um elemento radioativo, um g\u00e1s nobre que ocorre naturalmente em todo o mundo e \u00e9 o is\u00f3topo mais est\u00e1vel <sup>222<\/sup>Rn com meia-vida de 3,8 dias, produzido pela decomposi\u00e7\u00e3o do ur\u00e2nio e do r\u00e1dio. A raz\u00e3o para o momento de estresse para a sa\u00fade \u00e9 principalmente o pol\u00f4nio (Po), produto de decomposi\u00e7\u00e3o emissor de part\u00edculas \u03b1, com meia-vida de 138 dias, especialmente os is\u00f3topos <sup>210<\/sup>Po <sup>212<\/sup>bunda, <sup>214<\/sup>bunda, <sup>216<\/sup>bunda, <sup>218<\/sup>P\u00f4. A meia-vida biol\u00f3gica no corpo \u00e9 de 50 dias.<br>A radia\u00e7\u00e3o \u03b1 dificilmente \u00e9 prejudicial externamente, pois a profundidade de penetra\u00e7\u00e3o j\u00e1 \u00e9 absorvida na camada superior da pele. Como o rad\u00f4nio \u00e9 sol\u00favel na \u00e1gua pot\u00e1vel, trata-se de uma contamina\u00e7\u00e3o interna que tem efeito direto nas c\u00e9lulas e pode ser armazenada nos \u00f3rg\u00e3os.<br>O fator de pondera\u00e7\u00e3o da radia\u00e7\u00e3o \u00e9 20 e, portanto, representa vinte vezes mais nocividade do que a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o \u03b3 na mesma unidade de tempo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Radon_%E2%80%93_als_Heilmittel\"><\/span>Rad\u00e3o - como rem\u00e9dio<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Depois de o r\u00e1don ter sido descrito acima como prejudicial para a sa\u00fade, eis um aspeto contr\u00e1rio da sua utiliza\u00e7\u00e3o como rem\u00e9dio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Muitos spas em todo o mundo oferecem curas de rad\u00e3o baseadas na inala\u00e7\u00e3o de ar contendo rad\u00e3o e na ingest\u00e3o de \u00e1gua contendo rad\u00e3o. Predominantemente com <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/23864139\/\" target=\"_blank\" rel=\"noreferrer noopener\">doen\u00e7as reum\u00e1ticas<\/a> melhorias duradouras dos sintomas, mas tamb\u00e9m no caso de <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29116046\/\" target=\"_blank\" rel=\"noreferrer noopener\">Inflama\u00e7\u00e3o do trato respirat\u00f3rio superior e inferior<\/a>tal como demonstrado no estudo referido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Recomendamos tamb\u00e9m o livro de <a href=\"https:\/\/www.verlagdrkovac.de\/978-3-8300-8183-8.htm?bb=1\" target=\"_blank\" rel=\"noreferrer noopener\">RADIZ Centro de Documenta\u00e7\u00e3o e Informa\u00e7\u00e3o sobre o Rad\u00e3o Schlema e. V. (Ed.)<\/a>publicado pelo Dr. Kova\u010d, que tamb\u00e9m descreve o contexto m\u00e9dico dos efeitos do r\u00e1don no corpo humano.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Messgerate\"><\/span>Dispositivos de medi\u00e7\u00e3o<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Os contadores Geiger-M\u00fcller mencionados acima geralmente detectam radia\u00e7\u00e3o \u03b2 e \u03b3 no segmento de pre\u00e7o mais baixo. Os dispositivos de medi\u00e7\u00e3o que detectam a radia\u00e7\u00e3o \u03b1 custam mais de cerca de 600 euros.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dispositivos de medi\u00e7\u00e3o de rad\u00f4nio, incluindo calibra\u00e7\u00e3o, podem ser adquiridos por cerca de 200 euros.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dispositivos suficientes para usu\u00e1rios dom\u00e9sticos incluem o contador \u03b2\/\u03b3 <a href=\"https:\/\/www.amazon.de\/dp\/B071JWB7TJ?psc=1&amp;ref=ppx_yo2ov_dt_b_product_details\" target=\"_blank\" rel=\"noreferrer noopener\">GMC500+<\/a> da GQ, bem como o detector de rad\u00f4nio <a href=\"https:\/\/www.radonshop.com\/ftlab-radoneye-rd200-radon-gas-monitor-r222-messgeraet\" target=\"_blank\" rel=\"noreferrer noopener\">RadonEye<\/a> com conex\u00e3o Bluetooth do fabricante sul-coreano FTLab, que tamb\u00e9m est\u00e1 dispon\u00edvel em uma vers\u00e3o - infelizmente duas vezes mais cara - com conex\u00e3o WLAN.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambos os dispositivos possuem armazenamento de dados integrado e representa\u00e7\u00e3o num\u00e9rica e gr\u00e1fica das s\u00e9ries de medi\u00e7\u00e3o.<br>A bateria substitu\u00edvel de \u00edons de l\u00edtio do contador Geiger m\u00f3vel e estacion\u00e1rio pode ser carregada usando uma porta USB. O detector de rad\u00f4nio requer 12V DC, por exemplo, conectado a um banco de energia por meio de um conversor StepUp DCDC ou por meio de uma fonte de alimenta\u00e7\u00e3o plug-in, ou por meio de uma conex\u00e3o de 12V para carro.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Definition_Grenz-_Richt_und_Referenzwert\"><\/span>Defini\u00e7\u00e3o de limite, diretriz e valor de refer\u00eancia<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O significado desses tr\u00eas valores costuma ser confundido, ent\u00e3o aqui est\u00e1 a defini\u00e7\u00e3o correta:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Valor limite \u2013 n\u00e3o deve ser excedido<\/li>\n\n\n\n<li>Valor de refer\u00eancia \u2013 deve ser respeitado para garantir que os valores limite n\u00e3o sejam excedidos<\/li>\n\n\n\n<li>Valor de refer\u00eancia \u2013 \u00e9 a concentra\u00e7\u00e3o apenas aceita<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Interpretation_der_Messwerte\"><\/span>Interpreta\u00e7\u00e3o dos valores medidos<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A radia\u00e7\u00e3o radioativa natural est\u00e1 entre 0,03 e 0,08 \u03bcSv\/h. A exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o calculada ao longo de um ano \u00e9 determinada a partir de (0,03 x 24 x 365) \/ 100 = 0,2628 mS\/a .. (0,08 x 24 x 365) \/ 100 = 0,7008 mS\/a.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Os valores limite est\u00e3o muito sujeitos a interpreta\u00e7\u00e3o. Se pensarmos nos antigos valores-limite para raios X, hoje aplicam-se valores muito mais baixos porque agora podemos determinar que dano \u00e9 causado por qual dose.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hoje, cerca de 100 mS\/a s\u00e3o considerados perigosos para a sa\u00fade. Uma dose \u00fanica de 1 S causa doen\u00e7a de radia\u00e7\u00e3o, ou 5 S em casos 50% causa a morte dentro de um m\u00eas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A polui\u00e7\u00e3o por rad\u00f4nio varia muito dependendo da permeabilidade do solo e da ocorr\u00eancia de ur\u00e2nio ou r\u00e1dio, o que resulta em diferentes concentra\u00e7\u00f5es de rad\u00f4nio recomendadas como \u201cvalores limite\u201d.<br>Em m\u00e9dia podemos dizer que 100 Bq\/m<sup>3<\/sup> aplicar como limite para concentra\u00e7\u00f5es internas, mas tamb\u00e9m 200 Bq\/m<sup>3<\/sup> ainda s\u00e3o considerados aceit\u00e1veis em alguns pa\u00edses.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O rad\u00f4nio \u00e9 facilmente sol\u00favel em \u00e1gua e, portanto, tamb\u00e9m pode ser absorvido pela \u00e1gua pot\u00e1vel ou pela inala\u00e7\u00e3o de vapores de \u00e1gua ao cozinhar ou tomar banho. O sistema hidr\u00e1ulico reduz as concentra\u00e7\u00f5es de rad\u00f4nio misturando \u00e1gua com uma concentra\u00e7\u00e3o mais baixa de outras fontes ou arejando-a com oxig\u00eanio, o que faz com que o rad\u00f4nio escape parcialmente da \u00e1gua.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>As radia\u00e7\u00f5es ionizantes s\u00e3o impercept\u00edveis para o homem, inodoras, ins\u00edpidas e invis\u00edveis. Produz-se quando os \u00e1tomos das subst\u00e2ncias radioactivas decaem, como acontece em toda a natureza. Unidades No entanto, este decaimento at\u00f3mico pode ser medido. Antoine Henri Becquerel, juntamente com Marie e Pierre Curie, foi galardoado com o Pr\u00e9mio Nobel pela descoberta da radioatividade em 1903. Ap\u00f3s...&nbsp;<a href=\"https:\/\/csiag.de\/pt\/blog\/2023\/03\/01\/ionisierende-strahlung\/\" rel=\"bookmark\">Ler mais \"<span class=\"screen-reader-text\">Radia\u00e7\u00e3o ionizante<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1217],"tags":[1240,1230,1234,1229,1241,1253,1225,684,1239,1235,1242,1246,1245,1248,1249,1222,1252,1218,1226,1237,1236,1227,1221,1219,1244,1250,1251,1243,1247,103,1223,1231,1224,1232,1238,1220,1228],"class_list":["post-3553","post","type-post","status-publish","format-standard","hentry","category-ionisierende-strahlung","tag-alpha-strahlung","tag-antoine-henri","tag-aequivalenz-dosis","tag-becquerel","tag-beta-strahlung","tag-bodendurchlaessigkeit","tag-curie","tag-dosis","tag-durchdringungsfaehigkeit","tag-effektiv-dosis","tag-gamma-srahlung","tag-geiger-mueller-zaehler","tag-geiger-zaehler","tag-gmc500","tag-gmc500-2","tag-grenzwert","tag-innenraum-konzentration","tag-ionisierende-strahlung","tag-marie","tag-organ","tag-organ-dosis","tag-pierre","tag-polonium","tag-radium","tag-radon","tag-radon-belastung","tag-radon-konzentration","tag-radon-strahlung","tag-radoneye","tag-referenzwert","tag-richtwert","tag-rolf-sivert","tag-sievert","tag-strahlenwichtungsfaktor","tag-strahlungsart","tag-uran","tag-walther-mueller"],"acf":[],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/posts\/3553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/comments?post=3553"}],"version-history":[{"count":0,"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/posts\/3553\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/media?parent=3553"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/categories?post=3553"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.de\/pt\/wp-json\/wp\/v2\/tags?post=3553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}