{"id":4186,"date":"2023-04-29T20:14:33","date_gmt":"2023-04-29T20:14:33","guid":{"rendered":"https:\/\/csiag.de\/?p=4186"},"modified":"2024-05-23T08:01:16","modified_gmt":"2024-05-23T08:01:16","slug":"elektrosmog","status":"publish","type":"post","link":"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/","title":{"rendered":"Elektrosmog"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Innholdsfortegnelse<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Was_ist_eigentlich_Elektrosmog\" >Hva er egentlig elektrosmog?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Hochspannungsleitungen\" >H\u00f8yspentledninger<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Transformatoren-Stationen\" >Transformatorstasjoner<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Grenzwerte\" >Grenseverdier<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Niederfrequenz\" >Lav frekvens<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Hochfrequenz\" >H\u00f8y frekvens<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Handy-Strahlung\" >Str\u00e5ling fra mobiltelefoner<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#WLAN-Strahlung\" >WLAN-str\u00e5ling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Abschirmmasnahmen\" >Skjermingstiltak<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/#Materialien\" >Materialer<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesetid<\/span> <span class=\"rt-time\"> 6<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span><div class=\"pdfprnt-buttons pdfprnt-buttons-post pdfprnt-top-right\"><a href=\"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/posts\/4186?print=pdf\" class=\"pdfprnt-button pdfprnt-button-pdf\" target=\"_blank\" ><\/a><a href=\"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/posts\/4186?print=print\" class=\"pdfprnt-button pdfprnt-button-print\" target=\"_blank\" ><img decoding=\"async\" src=\"https:\/\/csiag.de\/wp-content\/plugins\/pdf-print\/images\/print.png\" alt=\"bildeutskrift\" title=\"Print Content\" \/><span class=\"pdfprnt-button-title pdfprnt-button-print-title\">Skriv ut<\/span><\/a><\/div>\n<p>Elektrosmog er et hett tema for mange mennesker og er gjenstand for mye kontrovers.<\/p>\n\n\n\n<p>Lovgivningen skal holde elektrosmog i sjakk ved hjelp av grenseverdier. Landspesifikke bestemmelser st\u00e5r i veien for en standardisering av tillatte verdier. Selve elektrosmogen er imidlertid identisk over hele verden. Standardiserte avtaler burde derfor v\u00e6re en selvf\u00f8lge.<\/p>\n\n\n\n<p>Forskjellen fra elektromagnetisk kompatibilitet (EMC): EMC-direktivet <a href=\"https:\/\/www.eu-richtlinien-online.de\/de\/verwaltungsvorschrift\/2014-30-eu\/206361928\" target=\"_blank\" rel=\"noreferrer noopener\">2014\/30\/EU<\/a> definerer spesifikasjoner for \u00e5 unng\u00e5 gjensidig elektromagnetisk interferens mellom elektriske og elektroniske enheter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Was_ist_eigentlich_Elektrosmog\"><\/span>Hva er egentlig elektrosmog?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>I dagligtalen brukes begrepet om elektriske, magnetiske og elektromagnetiske felt, for eksempel str\u00e5ling fra kabler i elektriske installasjoner, elektriske apparater, radio, TV, WLAN, mobiltelefoner, GPS, radar osv.<\/p>\n\n\n\n<p>Man skiller mellom lavfrekvente og h\u00f8yfrekvente str\u00e5lingskilder. Lavfrekvent er for eksempel nettspenningen p\u00e5 230 V, som har en frekvens p\u00e5 50 Hz. Jernbanens kj\u00f8reledninger opererer med en spenning p\u00e5 15 kV ved 16,67 Hz.<\/p>\n\n\n\n<p>S\u00e5 snart det flyter str\u00f8m gjennom en elektrisk leder, oppst\u00e5r det et vertikalt rettet magnetfelt rundt den. Likestr\u00f8m induserer et direkte magnetfelt, vekselspenning et vekslende magnetfelt p\u00e5 grunn av elektriske ladninger i bevegelse.<\/p>\n\n\n\n<p>Siden oppdagelsen av elektrisitet, som f\u00f8rst ble gjort av <em>Otto von Guericke<\/em> i sammenheng med hans elektrifiserende maskin, utviklingen av dynamomaskinen fra <em>Ernst Werner von Siemens<\/em> Frem til den f\u00f8rste elektriske trikken i Berlin i 1881 hadde vekslende elektriske felt allerede ledsaget mennesker. Men, som Paracelsus proklamerte, dosen gj\u00f8r giften.<\/p>\n\n\n\n<p>I dag er vi daglig omgitt av et mangfold av apparater som sender p\u00e5 ulike frekvenser og med ulik effekt, og som dermed genererer elektromagnetisk str\u00e5ling av varierende intensitet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hochspannungsleitungen\"><\/span>H\u00f8yspentledninger<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>H\u00f8yspentlinjer overf\u00f8rer vekselstr\u00f8m med ulik spenning. Man skiller mellom mellom- (opp til 30 kV), h\u00f8y- (opp til 110 kV) og ekstra h\u00f8yspentledninger (over 150 kV -&gt; 220 kV og 380 kV).<\/p>\n\n\n\n<p>H\u00f8yden p\u00e5 50 ... 110 kV-mastene er 22 meter h\u00f8ye, 220 kV-mastene er rundt 40 meter h\u00f8ye og 380 kV-linjene er installert i 83 meters h\u00f8yde.<br>Sistnevnte avgir rundt 200 V\/m og rundt 20 \u03bcT n\u00e5r de m\u00e5les direkte under kabelen p\u00e5 bakken. Det betyr at begge de m\u00e5lte verdiene ligger godt under de lovbestemte grenseverdiene p\u00e5 500 V\/m for elektrisk feltstyrke og 100 \u03bcT for magnetisk flukstetthet.<\/p>\n\n\n\n<p>Den h\u00f8yeste fluksdensiteten p\u00e5 rundt 52 \u03bcT kan m\u00e5les i en sideveis avstand p\u00e5 10 m fra en 380 kV h\u00f8yspentlinje. Ved en avstand p\u00e5 50 m krymper denne verdien til en tiendedel. Den maksimale verdien synker med opptil 10 % i midten under h\u00f8yspentlinjen.<\/p>\n\n\n\n<p>I en sideveis avstand p\u00e5 50 m fra h\u00f8yspentledningens ledningsbunt oppn\u00e5s en elektrisk feltstyrke p\u00e5 ca. 3 V\/m, noe som tilsvarer ca. 16 % av feltstyrken m\u00e5lt i en avstand p\u00e5 50 cm fra en bryterrekke med en belastning p\u00e5 ca. 2 000 W i hjemmet.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"348\" src=\"https:\/\/csiag.de\/wp-content\/uploads\/2023\/05\/EMF_Messungen.jpg\" alt=\"\" class=\"wp-image-4435\" srcset=\"https:\/\/csiag.de\/wp-content\/uploads\/2023\/05\/EMF_Messungen.jpg 800w, https:\/\/csiag.de\/wp-content\/uploads\/2023\/05\/EMF_Messungen-300x131.jpg 300w, https:\/\/csiag.de\/wp-content\/uploads\/2023\/05\/EMF_Messungen-768x334.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">M\u00e5ling fra bakken under en h\u00f8yspentluftledning - avstander fra nullpunktet (venstre bilde)<\/figcaption><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Transformatoren-Stationen\"><\/span>Transformatorstasjoner<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Transformatorstasjoner reduserer den innkommende mellomspenningen til vanlig husholdningsspenning p\u00e5 230 \/ 400 V. Denne prosessen avgir ogs\u00e5 magnetfelt. Ogs\u00e5 under denne prosessen oppst\u00e5r det magnetfelt.<\/p>\n\n\n\n<p>I likhet med h\u00f8yspentledninger antas ogs\u00e5 transformatoranlegg \u00e5 v\u00e6re helseskadelige. Slike anlegg er vanligvis bygget i prefabrikkert betong og har ventilasjon med st\u00e5lgitter og d\u00f8rer for vedlikeholdsarbeid.<\/p>\n\n\n\n<p>M\u00e5linger p\u00e5 en meters avstand viste 0 V\/m og 0,02 \u03bcT, i direkte kontakt med den omkringliggende prefabrikerte betongveggen en gjennomsnittsverdi p\u00e5 0 V\/m og 0,69 \u03bcT, og ved ventilasjonsspaltene 2 V\/m og 1,53 \u03bcT. S\u00e5 lave verdier finner man ikke engang i et normalt hjemmemilj\u00f8.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Grenzwerte\"><\/span>Grenseverdier<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Det er her det blir komplisert, fordi ulike frekvenser med ulike intensiteter representerer ulike eksponeringsscenarier, noe som igjen krever at det settes ulike grenseverdier.<\/p>\n\n\n\n<p>I tillegg er grenseverdier alltid basert p\u00e5 empiriske verdier. Selv Wilhelm Conrad R\u00f6ntgen var til \u00e5 begynne med ikke klar over risikoen ved r\u00f8ntgenstr\u00e5lene som er oppkalt etter ham, da han oppdaget dem 8. november 1895. Selv i 1980 var det enn\u00e5 ikke kjent at utilstrekkelig skjermede radarapparater ogs\u00e5 sender ut r\u00f8ntgenstr\u00e5ler, selv om den f\u00f8rste r\u00f8ntgenforskriften ble utstedt i 1941, som 31. desember 2018 ble erstattet av den endrede str\u00e5levernforskriften (<a href=\"https:\/\/www.gesetze-im-internet.de\/strlschv_2018\/index.html\" target=\"_blank\" rel=\"noreferrer noopener\">StrlSchV<\/a>) og juss (<a href=\"http:\/\/www.bgbl.de\/xaver\/bgbl\/start.xav?startbk=Bundesanzeiger_BGBl&amp;jumpTo=bgbl117s1966.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">StrlSchG<\/a>) har blitt erstattet. Grenseverdiene justeres ogs\u00e5 etter hvert som nye funn fremkommer og grensene skjerpes.<\/p>\n\n\n\n<p>Generelt, og uavhengig av eventuelle lovfestede grenseverdier, er eksponeringen lavere jo st\u00f8rre avstanden fra str\u00e5lekilden er.<\/p>\n\n\n\n<p>Energiabsorpsjonen i menneskekroppen fra f.eks. mobiltelefonstr\u00e5ling uttrykkes i W\/kg kroppsvekt som en s\u00e5kalt SAR-verdi (Specific Absorption Rate) og m\u00e5les i en avstand p\u00e5 mindre enn 5 mm. Den representerer effekten av elektromagnetisk str\u00e5ling som absorberes av ett kilo kroppsvekt. F\u00f8lgende m\u00e5lestandarder gjelder <a href=\"https:\/\/www.vde-verlag.de\/normen\/0800671\/din-en-62209-2-vde-0848-209-2-2020-07.html\" target=\"_blank\" rel=\"noreferrer noopener\">EN 62209-2<\/a> for kroppen, <a href=\"https:\/\/www.vde-verlag.de\/normen\/0800452\/din-en-62209-1-vde-0848-209-1-2017-11.html\" target=\"_blank\" rel=\"noreferrer noopener\">EN 62209-1<\/a> for hodet.<\/p>\n\n\n\n<p>Egnet, frekvensavhengig  <a href=\"#Abschirmma\u00dfnahmen\" target=\"_blank\" data-type=\"internal\" data-id=\"#Abschirmma\u00dfnahmen\" rel=\"noreferrer noopener\">Skjermingstiltak<\/a> redusere str\u00e5lingseksponeringen betraktelig.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Niederfrequenz\"><\/span>Lav frekvens<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Her er noen eksempler p\u00e5 elektromagnetisk str\u00e5ling (EF), elektromagnetisk feltstyrke (EMF) fra vanlige (lavfrekvente) enheter i en avstand p\u00e5 30 cm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>LED-TV<br>- EF 54 V\/m<br>- EMF 0,03 \u03bcT <\/li>\n\n\n\n<li>B\u00e6rbar PC-skjerm<br>- EF 3 V\/m<br>- EMF 0,03 \u03bcT<\/li>\n\n\n\n<li>Kaffemaskin<br>- EF 75 V\/m<br>- EMF 0,13 \u03bcT<\/li>\n\n\n\n<li>Hoover<br>- EF 35 V\/m<br>- EMF 1,88 \u03bcT<\/li>\n\n\n\n<li>Kj\u00f8leskap<br>- EF 12 V\/m<br>- EMF 0,2 \u03bcT<\/li>\n\n\n\n<li>Induksjonskomfyr<br>- EF 80 V\/m<br>- EMF 0,71 \u03bcT<br><\/li>\n<\/ul>\n\n\n\n<p>Grenseverdier for lavfrekvent elektromagnetisk str\u00e5ling er spesifisert i <a href=\"https:\/\/www.bfs.de\/DE\/themen\/emf\/nff\/schutz\/grenzwerte\/grenzwerte_node.html\" target=\"_blank\" rel=\"noreferrer noopener\">Forskrift om elektromagnetiske felt - 26. BImSchV<\/a> for ulike frekvensomr\u00e5der:<\/p>\n\n\n\n<p>Grenseverdiene for kj\u00f8reledninger for jernbane (16,67 Hz) og elektriske installasjoner (50 Hz) er 5 kV\/m ved 300 \u03bcT. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hochfrequenz\"><\/span>H\u00f8y frekvens<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Mobiltelefoner og mikrob\u00f8lger er radiofrekvent (RF) str\u00e5ling. Alle verdiene ble ogs\u00e5 m\u00e5lt i en avstand p\u00e5 30 cm. Verdiene for mobiltelefoner ble ogs\u00e5 m\u00e5lt i kontakt med huden.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mobiltelefon (for utg\u00e5ende samtaler og d\u00e5rlig dekning)<br>- EF 12 V\/m - hudkontakt 53 V\/m<br>- EMF0,05 \u03bcT<br>- RF (LTE, 2100 MHz) 5 mW\/m<sup>2<\/sup> - Hudkontakt 186 mW\/m<sup>2<\/sup><\/li>\n\n\n\n<li>Mikrob\u00f8lgeovn<br>- EF 50 V\/m<br>- EMF 2,2 \u03bcT<br>- RF 3,2 mW\/m<sup>2<\/sup> (2 450 MHz)<\/li>\n<\/ul>\n\n\n\n<p>Grenseverdier for h\u00f8yfrekvent elektromagnetisk str\u00e5ling er <a href=\"https:\/\/www.bfs.de\/DE\/themen\/emf\/hff\/schutz\/grenzwerte\/grenzwerte.html\" target=\"_blank\" rel=\"noreferrer noopener\">her<\/a> oppf\u00f8rt.<\/p>\n\n\n\n<p>For frekvenser fra 2 000 . 300 000 MHz anses opptil EF 61 V\/m \u00e5 v\u00e6re tillatt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Handy-Strahlung\"><\/span>Str\u00e5ling fra mobiltelefoner<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Str\u00e5lingen fra mobiltelefoner \u00f8ker n\u00e5r den mottatte feltstyrken avtar. Ettersom mobiltelefoner sender ut pulserende effekt, er intensiteten mye h\u00f8yere enn ved kontinuerlig gjennomsnittlig effekt.<\/p>\n\n\n\n<p>Det finnes GSM-repeatere (ikke tillatt i Tyskland) som bruker en mottaksantenne (retningsbestemt) p\u00e5 det h\u00f8yeste punktet og en senderantenne p\u00e5 eiendommen for \u00e5 fange opp det sterkere signalet i h\u00f8yden og str\u00e5le det ut med h\u00f8yere effekttetthet nederst p\u00e5 eiendommen, slik at mottaket blir bedre.<\/p>\n\n\n\n<p>Dette reduserer overf\u00f8ringseffekten til mobiltelefonen og reduserer eksponeringen for mobilstr\u00e5ling.<\/p>\n\n\n\n<p>Bruk av et kablet hodesett reduserer eksponeringen for mobilstr\u00e5ling p\u00e5 grunn av den \u00f8kte avstanden til hodet, og det samme gj\u00f8r bruk av et BT-headset (2 400 MHz). SAR-verdien for et BT-headset (klasse 3 - overf\u00f8ringseffekt opp til 1 mW) er 0,003 W\/kg, noe som er mye lavere enn for eksempel en iPhone 11 med 0,95 W\/kg. Andre BT-klasser er 2 med opptil 2,5 mW og 3 med opptil 100 mW. Sistnevnte er like kritisk som str\u00e5ling fra mobiltelefoner.<\/p>\n\n\n\n<p>Et alternativ til d\u00e5rlig mobildekning i hjemmemilj\u00f8et, med p\u00e5f\u00f8lgende h\u00f8yere str\u00e5lingseksponering, er for eksempel en VoIP-telefon, som kan kobles til via DSL-tilkoblingen hvis man ikke allerede har en fasttelefon.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"WLAN-Strahlung\"><\/span>WLAN-str\u00e5ling<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Rutere brukes i husholdninger, p\u00e5 kontorer osv. til tr\u00e5dl\u00f8s videresending av kablede Internett-tilkoblinger.<\/p>\n\n\n\n<p>De opererer i to frekvensomr\u00e5der, nemlig 2,4 GHz og 5 GHz. Dataoverf\u00f8ringshastigheten er ogs\u00e5 h\u00f8yere ved h\u00f8yere frekvenser, noe som er fordelaktig for for eksempel videooverf\u00f8ring.<\/p>\n\n\n\n<p>Hvis du lider av EHS (el-overf\u00f8lsomhet), men er helt avhengig av WLAN, b\u00f8r du sl\u00e5 av WLAN i 5 GHz-b\u00e5ndet i ruteren og holde en maksimal avstand fra ruteren eller dens antenner som er akkurat akseptabel med tanke p\u00e5 dataoverf\u00f8ringshastigheten.<\/p>\n\n\n\n<p>Dette reduserer den elektriske feltstyrken og dermed str\u00e5lingseksponeringen av kroppen og de helsemessige konsekvensene av dette.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Abschirmma\u00dfnahmen\"><span class=\"ez-toc-section\" id=\"Abschirmmasnahmen\"><\/span>Skjermingstiltak<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Det beste skjermingstiltaket er \u00e5 unng\u00e5 og sl\u00e5 av str\u00e5lingskilder som mobiltelefoner, WLAN-rutere, repeatere osv.<\/p>\n\n\n\n<p>Eksterne str\u00e5lingskilder som man ikke selv kan p\u00e5virke, er derfor en god grunn til \u00e5 se n\u00e6rmere p\u00e5 temaet avskjerming. Selv om str\u00e5ling neppe kan elimineres helt ved hjelp av bygningsmessige tiltak, kan den reduseres kraftig ved refleksjon eller omdanning til varme.<\/p>\n\n\n\n<p>Det finnes en rekke leverand\u00f8rer av ulike skjermingsmaterialer som mer eller mindre oppfyller form\u00e5let sitt. S\u00e5 hvilket produkt b\u00f8r du velge?<\/p>\n\n\n\n<p>Det f\u00f8rste steget er \u00e5 finne ut hvilken utstr\u00e5lt effekt som b\u00f8r reduseres med hvor mye ved hvilken frekvens. For \u00e5 gj\u00f8re dette m\u00e5 det foretas m\u00e5linger for deretter \u00e5 avgj\u00f8re hvilken <a href=\"https:\/\/csiag.de\/nb\/forplantningsdemping-av-radiobolger\/#Daempfung\" target=\"_blank\" rel=\"noreferrer noopener\">Demping<\/a> er \u00f8nsket i forhold til de m\u00e5lte frekvensene.<br>Til sammenligning: Vil du bo ved siden av en sirkelsag (10 dB skjerming), en sidevei med trafikk p\u00e5 dagtid (50 dB skjerming = 99,999 %) eller vil du helst bo med stille l\u00f8vst\u00f8y (80 dB skjerming = 99,999 999 %)?<\/p>\n\n\n\n<p>Produsentens spesifikasjoner for skjermingseffektivitet m\u00e5 evalueres i henhold til dette.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Materialien\"><\/span>Materialer<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Anbefales <a href=\"https:\/\/aaronia.de\/abschirmung\/\" target=\"_blank\" rel=\"noreferrer noopener\">Materialer<\/a> tilbys av kjente produsenter som AARONIA AG. Produktene deres brukes til \u00e5 skjerme LF- og HF-signaler opp til GHz-omr\u00e5det (26 GHz). Noen av produktene er selvklebende eller kan p\u00e5f\u00f8res med vanlig sparkel, for eksempel klister under veggpanel eller tapet, og er laget av spesielle kobber\/nikkel- eller s\u00f8lvpolyester-stoffer med skjermingsegenskaper p\u00e5 opptil over 100 dB n\u00e5r de er jordet.<\/p>\n\n\n\n<p>Det er viktig \u00e5 s\u00f8rge for at skinnene overlapper hverandre med ti centimeter for \u00e5 sikre en elektrisk forbindelse under skinnene. D\u00f8rkarmer og d\u00f8rer m\u00e5 ogs\u00e5 monteres med egnede materialer.<\/p>\n\n\n\n<p>AARONIA-produktene som tilbys, brukes blant annet av BASF, BMW, Daimler Chrysler, DLR, EADS, EnBW og Fraunhofer-instituttet, og taler dermed for seg selv n\u00e5r det gjelder effektivitet og kvalitet.<\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#ff0000\">Alt arbeid i forbindelse med elektriske anlegg m\u00e5 kun utf\u00f8res av kvalifiserte fagfirmaer!<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesetid<\/span> <span class=\"rt-time\"> 6<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span> Das Thema Elektrosmog erhitzt viele Gem\u00fcter und wird \u00fcberaus kontrovers diskutiert. Gesetze sollen Elektrosmog mit Grenzwerten im Zaum halten. L\u00e4nderspezifische Festlegungen stehen einer Vereinheitlichung zul\u00e4ssiger Werte im Wege. Elektrosmog an sich ist jedoch weltweit identisch. Einheitliche Vereinbarungen sollten also auf der Hand liegen. Abgrenzung zur ElektroMagnetischen Vertr\u00e4glichkeit (EMV): die EMV-Richtlinie 2014\/30\/EU definiert Vorgaben zur&hellip;&nbsp;<a href=\"https:\/\/csiag.de\/nb\/blog\/2023\/04\/29\/elektrosmog\/\" rel=\"bookmark\">Les mer \"<span class=\"screen-reader-text\">Elektrosmog<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1525,1302,1078,354],"tags":[3358,3360,1555,1556,1554,551,1527,1528,1587,1533,1589,1526,1551,557,1432,1118,1222,1549,948,1550,1538,1540,447,1557,725,1558,1537,1539,1559,1536,1548,1545,574,1339,1546,1552,1542,682,1553,1544,1535,835,563],"class_list":["post-4186","post","type-post","status-publish","format-standard","hentry","category-elektrosmog","category-funktechnik","category-medizin","category-medizin-gesundheit","tag-3358","tag-5-ghz","tag-abschirmmassnahmen","tag-absorptionsrate","tag-abstand","tag-bt","tag-db","tag-dba","tag-ehs","tag-elektroinstallation","tag-elektrosensibilitaet","tag-elektrosmog","tag-emv","tag-frequenz","tag-gleichspannung","tag-gps","tag-grenzwert","tag-gsm","tag-handy","tag-headset","tag-hf","tag-hochfrequenz","tag-leistung","tag-leistungsdichte","tag-lte","tag-materialien","tag-nf","tag-niederfrequenz","tag-produkte","tag-radar","tag-repeater","tag-roentgenverordnung","tag-router","tag-sar","tag-strahlenbelastung","tag-strahlenschutzgesetz","tag-strahlenschutzverordnung","tag-strahlungsquelle","tag-strlschc","tag-strlschg","tag-tv","tag-wechselspannung","tag-wlan"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/posts\/4186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/comments?post=4186"}],"version-history":[{"count":0,"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/posts\/4186\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/media?parent=4186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/categories?post=4186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.de\/nb\/wp-json\/wp\/v2\/tags?post=4186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}